Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
1.
Arch. argent. pediatr ; 119(5): e428-e434, oct. 2021. tab, ilus
Article in English, Spanish | LILACS, BINACIS | ID: biblio-1292101

ABSTRACT

Introducción. En pediatría, el filtrado glomerular (FG) se puede calcular con el clearance (depuración) de creatinina medida corregida en ml/min/1,73 m2, o se puede estimar según la fórmula de Schwartz (FGe = talla/creatinina plasmática x k). La constante k depende del método de determinación de creatinina plasmática: k = 0,55 para el método colorimétrico de Jaffe, y k =0,413 para el método enzimático. Nuestro laboratorio utiliza el método colorimétrico cinético compensado (MCCC), se observan discordancias entre el FG estimado y el medido.Hipótesis: Los valores de k propuestos no se ajustan al MCCC de creatinina plasmática. Objetivo. Calcular el valor de k que permita estimar el FG mediante la cuantificación de la creatinina con el MCCC. Métodos. Diseño descriptivo correlacional. Se incluyeron pacientes de entre 3 y 18 años con FG normal o alterado atendidos en el Servicio de Nefrología Infantil entre julio de 2017 y enero de 2018 con control de esfínteres y firma del consentimiento. Se excluyeron pacientes desnutridos y con mielomeningocele. Las variables estudiadas fueron: creatinina plasmática y urinaria, talla y diuresis de 24 horas. Resultados. Se analizaron 184 pacientes, con una edad media de 10 años. La mediana del clearance de creatinina medido corregido fue de 123 ml/min/1,73 m2. La correlación lineal entre la talla y la creatinina plasmática y el clearance de creatinina medido corregido arrojó un valor de k de 0,499 (r = 0,974 y r2 = 0,949). La correlación lineal entre el FG estimado (k = 0,499) y el clearance de creatinina medido corregido mostró un coeficiente b = 0,999 (r = 0,951 y r2= 0,903). Conclusión. Según este estudio, la constante que permite estimar el filtrado glomerular al cuantificar la creatinina plasmática con el método colorimétrico cinético compensado es de 0,499.


Introduction. In pediatrics, glomerular filtration rate (GFR) may be estimated by measured corrected creatinine clearance (mcCrCl) (mL/min/1.73 m2) or the Schwartz formula (eGFR = height/plasma creatinine x k). The constant k depends on the plasma creatinine determination method: k = 0.55 for the Jaffe colorimetric method and k = 0.413 for the enzymatic method. Our laboratory uses the compensated kinetic colorimetric assay (CKC), and differences are observed between the estimated and measured GFR.Hypothesis: The proposed values of k do not adjust to the CKC method for plasma creatinine. Objective. To calculate a k value that allows to estimate GFR through creatinine measurement with CKC. Methods. Correlational, descriptive design. Patients aged 3-18 years seen at the Division of Pediatric Nephrology between July 2017 and January 2018 with normal or altered GFR, bladder and bowel control, and signed consent were included. Malnourished and myelomeningocele patients were excluded. Studied variables were plasma and urine creatinine, height, and 24-hour urine output. Results. A total of 184 patients were analyzed, their mean age was 10 years. Median mcCrCl was 123 mL/min/1.73 m2. The linear correlation between height and plasma creatinine and mcCrCl resulted in a k value of 0.499 (r = 0.974 and r2 = 0.949). The linear correlation between the estimated GFR (k = 0.499) and mcCrCl resulted in a 0.999 ß coefficient (r = 0.951 and r2 = 0.903). Conclusion. According to this study, the constant that allows to estimate GFR when measuring plasma creatinine with the CKC method is 0.499.


Subject(s)
Humans , Child, Preschool , Child , Adolescent , Pediatrics , Epidemiology, Descriptive , Creatinine , Glomerular Filtration Rate
2.
Vive (El Alto) ; 3(9): 227-246, dic. 2020. ilus
Article in Spanish | LILACS | ID: biblio-1252340

ABSTRACT

INTRODUCCIÓN: las infecciones fúngicas ocasionadas por levaduras del género Cándida son extremadamente comunes en mujeres de edad reproductiva, y constituyen un motivo de atención medica de salud. OBJETIVO: evaluar la susceptibilidad de Cándidas spp, mediante el método colorimétrico (Integral Yeast System Plus). MÉTODO: fue de tipo descriptivo, transversal; se recopiló información mediante observación directa en campo y el análisis documental para obtener información bibliográfica de tipo secundaria. RESULTADOS: de los 72 casos encontrados de Cándida Albicans revela que son susceptibles a la anfotericina B (2ug/ml); de los 5 casos encontrados de Cándida Krusei revela que son sensibles a la Anfotericina B (2ug/ml); De 1 caso encontrado de Cándida Parapsilosis revela sensibilidad en la Nistatina (1.25ug/ml). En este estudio la prevalencia de la infección por Cándida fue del (44.98%). CONCLUSIONES: Cándida Albicans fue la especie más común aislada en las mujeres embarazadas representando un 72%, En la evaluación de la susceptibilidad a través del kit Integral System Yeast Plus se obtuvo que Cándida Albicans es susceptible a Anfotericina B, Flucitosina entre otros, en Cándida Glabrata se obtuvo que es sensible a la Nistatina, Anfotericina B, susceptible entre otros, en Cándida Krusei se obtuvo que es sensible a la Anfotericina B, Clotrimazol, Miconazol, susceptibles a la Nistatina, Voriconazol y resistente a la Flucitosina, Ketoconazol, Itraconazol y Fluconazol.


INTRODUCTION: fungal infections caused by yeast of the genus Candida are extremely common in women of reproductive age, and constitute a reason for medical health care. OBJECTIVE: to evaluate the susceptibility of Candida spp, using the colorimetric method (Integral Yeast System Plus). METHOD: it was descriptive, transversal; Information was collected through direct observation in the field and documentary analysis to obtain secondary bibliographic information. RESULTS: of the 72 cases found, Candida Albicans reveals that they are susceptible to amphotericin B (2ug / ml); of the 5 cases found, Candida Krusei reveals that they are sensitive to Amphotericin B (2ug / ml); Of 1 case found of Candida Parapsilosis reveals sensitivity in Nystatin (1.25ug / ml). In this study, the prevalence of Candida infection was (44.98%). CONCLUSIONS: Candida Albicans was the most common species isolated in pregnant women, representing 72%. In the evaluation of susceptibility through the Integral System Yeast Plus kit it was obtained that Candida Albicans is susceptible to Amphotericin B, Flucytosine among others, in Candida Glabrata was obtained that it is sensitive to Nystatin, Amphotericin B, susceptible among others, in Candida Krusei it was obtained that it is sensitive to Amphotericin B, Clotrimazole, Miconazole, susceptible to Nystatin, Voriconazole and resistant to Flucytosin, Ketoconazole, Itraconazole and Fluconazole.


INTRODUÇÃO: as infecções fúngicas causadas por leveduras do gênero Candida são extremamente comuns em mulheres em idade reprodutiva e constituem motivo de cuidados médicos. OBJETIVO: avaliar a suscetibilidade de Candida spp, por meio do método colorimétrico (Integral Yeast System Plus). MÉTODO: foi descritivo, transversal; as informações foram coletadas por meio de observação direta em campo e análise documental para obtenção de informações bibliográficas secundárias. RESULTADOS: Dos 72 casos encontrados, Cândida Albicans revelou ser suscetíveis à anfotericina B (2ug /ml); dos 5 casos encontrados, Candida Krusei revela que são sensíveis à Anfotericina B (2ug / ml); de 1 caso encontrado de Candida Parapsilosis revela sensibilidade na Nistatina (1,25ug / ml). Neste estudo, a prevalência de infecção por Candida foi (44,98%). CONCLUSÕES: Cândida Albicans foi a espécie mais comum isolada em gestantes, representando 72%. Na avaliação da susceptibilidade através do kit Integral System Yeast Plus foi obtido que Candida Albicans é suscetível à Anfotericina B, Flucitosina entre outras, em Cândida Glabrata foi obtido que é sensível a Nistatina, Anfotericina B, suscetível entre outras, em Candida Krusei foi obtido que é sensível a Anfotericina B, Clotrimazol, Miconazol, suscetível a Nistatina, Voriconazol e resistente a Flucitosina, Cetoconazol, Itraconazol e Fluconazol.


Subject(s)
Humans , Female , Pregnancy , Adult , Candida , Candida albicans , Amphotericin B , Colorimetry , Candida glabrata , Pregnant Women , Fluconazole , Prevalence , Clotrimazole , Itraconazole , Voriconazole , Flucytosine , Candida parapsilosis , Infections , Miconazole
3.
Hig. aliment ; 33(288/289): 1007-1011, abr.-maio 2019. tab
Article in Portuguese | LILACS, VETINDEX | ID: biblio-1482088

ABSTRACT

Foram utilizados 40 cordeiros machos distribuídos casualmente em quatro tratamentos e dez repetições. Ao final do experimento os animais foram abatidos, para obtenção das carcaças e análise qualitativa da carne, onde foi utilizado o Longissimus lumborum. As leituras foram realizadas com auxílio de um colorímetro, através de três mensurações em diferentes pontos do músculo, utilizando-se os valores médios de cromaticidades L*, a* e b* para representação da coloração. Os resultados da análise de regressão demonstraram que não houve influência da substituição do milho pela glicerina bruta sobre a colorimetria da carne. Conclui-se que a glicerina bruta pode substituir o milho sem que influencie nas características qualitativas da carne de cordeiros, não alterando os parâmetros físico-químicos de cromaticidade do músculo.


Subject(s)
Male , Animals , Red Meat/analysis , Color , Glycerol/administration & dosage , Glycerol/adverse effects , Sheep/physiology , Colorimetry , Food Quality , Animal Feed
4.
Ciênc. rural ; 47(2): e20160195, 2017. tab
Article in English | LILACS | ID: biblio-828453

ABSTRACT

ABSTRACT: This study evaluated the yield, color, and chemical composition of commercial cuts (tail, sirloin cut, back fillet, and thigh) of Pantanal caiman meat in both sexes. The yield of tail was higher than other cuts, and the yield of females (17.0%) was higher than males (15.9%). The thigh of males had lower protein content (20.8%) compared with other cuts. Females showed a higher lipid content in the tail (2.4%) and thigh (0.8%) compared with males (1.7% and 0.4%, respectively). The tail presented the greatest content of monounsaturated fatty acids (45.2%) and higher n6/n3 ratio (4.6). Although lightness was not different among cuts or between sexes, there were differences in color. Males have more yellowish meat compared with females. Thigh and back fillet were more reddish when compared to sirloin cut and tail, regardless of sex. In conclusion, female tail meat provided greater yield and lipid content than males, and this result was statistically significant. These findings can help producers and consumers alike, better understand yield, quality, and nutritional quality of Pantanal caiman meat.


RESUMO: Objetivando avaliar rendimento, cor e composição química dos cortes comerciais (cauda, filé de lombo, filé de dorso e coxa) da carne do jacaré-do-Pantanal nos diferentes sexos, foram processados 20 animais, sendo estes, dez fêmeas (3677g) e dez machos (3510g). Não houve interação significativa (P>0,05) entre cortes comerciais e sexo para peso dos cortes, teor de umidade e cor. O rendimento da cauda foi superior aos demais cortes, sendo o rendimento das fêmeas (17.0%) superior ao dos machos (15,9%). A coxa dos machos apresentou menor teor de proteína (20,8%), em relação aos demais cortes. As fêmeas apresentaram maior teor de lipídeos na cauda (2,4%) e na coxa (0,8%), em relação aos machos (1,7% e 0,4%, respectivamente). A cauda apresentou maior quantidade de ácidos graxos monoinsaturados (45,2%) e maior razão n6/n3 (4,6). A luminosidade não foi diferente entre cortes e sexos. Os machos apresentaram carne com coloração mais amarelada em relação às fêmeas, e a coxa e o filé de dorso tiveram cor mais avermelhada, comparadas ao filé de lombo e cauda, independente do sexo. Concluiu-se que houve influência do sexo no corte de cauda, para o teor de lipídios e rendimento, sendo que a fêmea apresentou rendimento e lipídeos maiores que o macho.

5.
Bauru; s.n; 2017. 84 p. ilus, tab.
Thesis in Portuguese | LILACS, BBO | ID: biblio-883241

ABSTRACT

O propósito deste trabalho foi avaliar, in-vitro, a alteração de cor da cerâmica de dissilicato de lítio, após o envelhecimento artificial acelerado (EAA), variando-se os seguintes aspectos: processo de confecção (cerâmica monolítica e com infraestrutura coberta por cerâmica de revestimento), espessuras de 1,5 e 2,0mm e substratos de resina e liga metálica, com e sem cimento. Para isso foram confeccionadas 40 pastilhas de cerâmica IPS e.max Press, que foram divididas em 2 grupos (n=20): LT (cerâmica de baixa translucidez na cor A2) e HO (cerâmica de alta opacidade). Neste grupo as pastilhas foram confeccionadas com 0,5mm de espessura e, posteriormente, revestidas com a cerâmica IPS e.max Ceram na cor A2 e com espessuras de 1,0 e 1,5mm. Foram utilizados substratos em resina composta (n=20) e em liga metálica (cobre-alumínio) (n=20). Para a cimentação foi utilizado o cimento de polimerização dual Variolink II, na cor translúcida. A leitura da cor foi realizada em um espectrofotômetro (Minolta CM2600d), equipado com fonte de luz padrão D65 (luz do dia). A cor determinada no aparelho é expressa em coordenadas CIE L* a* b* e os valores correspondentes foram utilizados para calcular o E. Foram feitas as seguintes comparações: discos de cerâmica antes do EAA vs discos de cerâmica cimentadas sobre os substratos antes do EAA; discos de cerâmica cimentadas sobre os substratos antes do EAA vs discos de cerâmica cimentadas sobre os substratos após o EAA; discos de cerâmica antes do EAA vs discos de cerâmica cimentadas sobre os substratos após o EAA; discos de cerâmica antes do EAA vs discos de cerâmica após o EAA. Os dados foram submetidos a análise estatística (ANOVA) a 3 critérios e (ANOVA) a 2 critérios e testes de Tukey, p<0,05). Os resultados mostraram que: 1. os grupos somente de discos de cerâmica vs discos de cerâmica com 1,5 e 2,0mm de espessuras, cimentadas em substratos de resina e liga metálica, antes do EAA. O menor valor encontrado de E (E=3,6) foi com o grupo de discos da cerâmica HOA2 com 2mm de espessura cimentados em substrato de metal, seguido pelo grupo da mesma cerâmica com 1,5mm de espessura cimentada em substrato de resina. O maior valor encontrado (E=10,0) foi com os discos de cerâmica LTA2 com 1,5 e 2mm de espessuras e cimentados em substrato de metal; 2. os grupos com discos de cerâmicas com 1,5 e 2,0mm de espessuras e cimentados em substratos de resina e liga metálica antes do EAA vs o mesmo grupo após EAA. Os grupos de discos com a cerâmica HOA2 com 2mm de espessura cimentados em substrato de metal teve menor alteração de cor (E=1,1) e a maior alteração de cor ocorreu com o grupo da cerâmica LTA2 com 2mm de espessura cimentada em substrato de metal (E=2,1); 3. os grupos somente com discos de cerâmica antes do EAA vs grupos de cerâmicas com discos de 1,5 e 2,0mm de espessuras e cimentados em substratos de resina e liga metálica após o EAA. O menor valor encontrado (E=3,7) foi com a cerâmica HOA2 com revestimento e 2mm de espessura cimentada em substrato de metal. O maior valor encontrado (E=10,0) foi o da cerâmica LTA2 com 1,5 e 2mm de espessuras cimentadas em substrato de metal; 4. os grupos discos de cerâmica, antes e após o processo de EAA O grupo que teve menor alteração de cor foi o da cerâmica HOA2 com 1,5mm (E=0,6). O grupo que teve maior alteração de cor foi o da cerâmica LTA2 com 2mm (E=2,2). Concluiu-se que o EAA causou alteração na cor final das cerâmicas de dissilicato de lítio, levando-se em conta as variáveis pesquisadas.(AU)


The purpose of this in vitro study was to evaluate the color changing of the lithium disilicate ceramic discs after accelerated artificial aging (AAA) varying the following aspects: manufacturing process (monolithic ceramic and infrastructure with ceramic covering), thickness of the ceramic (1.5 and 2.0 mm) and abutment substrate (composite resin and alloy), with and without cement. Forty ceramic discs were fabricated with ceramic IPS e.max Press and divided into two groups (n = 20): LT (low translucency, shade A2) and HO (high opacity). In the HO group, the discs were fabricated with a thickness of 0.5 mm of the IPS e.max Ceram combined with a thickness of 1 or 1.5mm of veneering ceramic, shade A2. The abutments substrates were fabricated with composite resin (n = 20) and metallic alloy (n = 20). The resin cement used was Variolink II translucent color. Color was measured with a spectrophotometer and expressed in CIE L * a * b * coordinates. Color differences (E) were calculated. The data were analyzed with ANOVA and the Tukey HSD test (p <0.05).The results showed that 1.in the groups of ceramic discs vs. ceramic discs with 1.5 and 2.0mm thickness, cemented on resin substrates and metal alloy, before AAA, the lowest value of E (E = 3,6) was obtained for HOA2 ceramic discs with 2mm thickness cemented in metal substrate, followed by ceramic discs with 1.5mm thickness cemented in substrate of resin. The highest value (E = 10.0) was observed for ceramic discs LTA2 with 1.5 and 2mm thickness and cemented in metal substrate; 2. In the groups with ceramic discs with 1.5 and 2.0mm thickness and cemented on resin and metal substrates prior to AAA vs the same group after AAA, the HOA2 ceramic discs with 2mm thickness cemented on a metal substrate had the smallest color change (E = 1,1) and the largest occurred for LTA2 with 2mm thickness and cemented in metallic substrate (E = 2.1); 3. In the groups of ceramic discs before AAA vs groups of ceramic with discs of 1.5 and 2.0mm of thickness and cemented on resin substrates and metal alloy after AAA, the lowest value (E = 3,7) was obtained for HOA2 veneering ceramic 2mm thickness cemented on a metal substrate. The highest value found (E = 10.0) was for LTA2 ceramic with 1.5 and 2mm thickness cemented on a metal substrate; 4. comparing the groups of ceramic discs before and after the AAA process, the lowest color change was obtained for HOA2 ceramic with 1.5mm (E = 0.6) and the greatest color change was fore LTA2 ceramic with 2mm (E = 2.2). It was concluded that the AAA caused alteration in the final color of the lithium disilicate ceramics, taking into account the variables studied.(AU)


Subject(s)
Ceramics/chemistry , Dental Porcelain/chemistry , Dental Prosthesis Design , Prosthesis Coloring , Resin Cements/chemistry , Analysis of Variance , Color , Colorimetry , Materials Testing , Metal Ceramic Alloys , Reproducibility of Results , Spectrophotometry , Time Factors
6.
São Paulo; s.n; s.n; 2016. 151 p. tab, graf, ilus.
Thesis in Portuguese | LILACS | ID: biblio-847720

ABSTRACT

A proposta da presente tese foi desenvolver dispositivos inteligentes (língua e nariz eletrônicos/ colorimétrico) de baixo custo para discriminar amostras de alimentos contaminados quimicamente e biologicamente. Um dispositivo "optoeletrônico" à base de membranas poliméricas coloridas com indicadores de pH foi utilizado para discriminar compostos voláteis emitidos por micro-organismos (aminas liberadas pelos processos de deterioração dos alimentos e que são produto da descarboxilação de aminoácidos em alimentos predominantemente proteicos). As aminas avaliadas nesse estudo foram: isobutilamina, isopentilamina e trietilamina. O limite de detecção de 5 ppm das aminas foi alcançado utilizando o dispositivo "optoeletrônico" e, esse sistema, também foi testado em amostras reais de carne contaminadas obtendo uma boa discriminação das amostras com e sem as aminas. Aminas biogênicas (cadaverina, tiramina e putrescina) também foram testadas obtendo uma separação pelo gráfico de escores. Em uma segunda etapa o dispositivo também foi avaliado para discriminar quatro espécies de bactérias (Klebsiella pneumoniae, Proteus vulgaris, Proteus mirabilis e Escherichia coli) incubadas a 37°C e 25°C. Em ambos os casos o dispositivo inteligente utilizou um smartphone para registrar as imagens que atuou como detector para extração dos dados de RGB das imagens. A partir dessas informações (valores de RGB), as ferramentas quimiométricas PCA (do inglês Principal Component Analysis, Análise de Componentes Principais) e HCA (do inglês Hierarchical Cluster Analysis, Análise de Agrupamentos Hierárquicos) foram utilizadas para discriminar as amostras e a k-NN (do inglês kth Nearest Neighbor, k- vizinhos mais próximos) para validar o método. Em uma terceira etapa, uma língua eletrônica voltamétrica foi fabricada para discriminar amostras de leite adulteradas com melamina, ureia e formaldeído contendo concentrações finais de 0,95; 4,16 e 10,0 mmol L-1, respectivamente. Essa língua voltamétrica foi composta por três eletrodos metálicos: platina, ouro e cobre e dados voltamétricos foram utilizados como dados de entrada para as ferramentas quimiométricas (PCA e HCA). Foram testados três tipos de leite (integral, desnatado e semidesnatado) de três diferentes marcas e todos eles puderam ser discriminados com sucesso. O trabalho também apresenta a utilização de MIPs (polímeros molecularmente impressos - do inglês, molecularly imprinted polymers) como alternativa para detecção e discriminação de alimentos contaminados fazendo uso da impressão (cavidades) de substâncias químicas contaminantes ou das proteínas específicas de cada micro-organismo presente no processo de deterioração dos alimentos


The present thesis aimed at development of low cost smart devices (electronic tongue and colorimetric nose) to discriminate chemically and biologically contamination in food samples. An "optoelectronic" plastic-based device with colored membranes contained pH indicator was used to discriminate volatile compounds released by microorganisms, due to the deterioration process of protein in food by the organisms. The amines evaluated in this study were: isobutylamine, isopentylamine and triethylamine, achieving a detection limit of 5 ppm. Such system was also tested in real meat samples contaminated with individual amines obtained a good discrimination of samples with and without studied compounds. Biogenic amines (cadaverine, tyramine and putrescine) were also tested and discriminated. In a second step, the device was also evaluated to discriminate four bacteria species (Klebsiella pneumoniae, Proteus vulgaris, Proteus mirabilis and Escherichia coli) incubated at 37 ° C and 25 ° C. In both cases, a smartphone was used as detector to extract RGB values of the samples. From extracted information (RGB values), the chemometric tools PCA (Principal Component Analysis) and HCA (Hierarchical Cluster Analysis) were used to discriminate samples and k-NN (kth Nearest Neighbor) was evaluated to validate the method. In a third stage, a voltammetric electronic tongue was developed to discriminate adulterated milk samples with melamine, urea and formaldehyde. This voltammetric electronic tongue was fabricated using three working electrodes: platinum, gold and copper and the voltammetric data was used as input data for chemometric tools (PCA and HCA). Three types of milk (whole, skimmed and semi-skimmed) from three different brands were tested and all of them could be successfully discriminated


Subject(s)
Food Contamination/prevention & control , Electronic Nose , Bacteria , /analysis , Biological Pollutants , Colorimetry/instrumentation , Food Pollutants, Chemical , Foodborne Diseases/prevention & control
7.
Rev. cuba. farm ; 49(2)abr.-jun. 2015. ilus, tab
Article in Spanish | LILACS, CUMED | ID: lil-776401

ABSTRACT

Introducción: la complejidad y diversidad estructural de los polisacáridos capsulares de Streptococcus pneumoniae hace que la metodología analítica necesaria para la caracterización y control de calidad sea engorrosa. El método colorimétrico m‒hidroxibifenil desarrollado por Blumenkrantz y Asboe‒Hansen en el año 1973, permite contrarrestar las desventajas del método propuesto en la Farmacopea Europea 6ta Edición, 2011. Objetivo: validar el método m‒hidroxibifenilo para cuantificar ácido urónico en polisacáridos purificados de streptococcus pneumoniae. Métodos: se determinó el tiempo de vigencia de la solución de tetraborato de sodio responsable de generar la respuesta analítica y se seleccionó una metodología para la cuantificación de ácido urónico por el método del m‒hidroxibifenilo se emplea una solución estándar de ácido galacturónico a 1 mg/mL. Se realizó una evaluación de los parámetros de validación: linealidad, exactitud, precisión, rango y especificidad, según exigencias actuales. Además se comparó con el método del carbazol descrito en la Farmacopea Europea 6ta Edición, 2011 para la cuantificación de ácido urónico. Resultados: se demostró que el tiempo de vida útil de la solución de tetraborato de sodio fue de 24 h. El método del m‒hidroxibifenilo fue específico, lineal, exacto y preciso en el rango de 2‒20 µg/mL porque se cumplieron satisfactoriamente los criterios de aceptación establecidos para cada uno de ellos. La comparación del método propuesto con el método normalizado reveló que no existieron diferencias estadísticamente significativas entre ambos(AU) Conclusión: el método colorimétrico del m‒hidroxibifenilo resultó válido para el control de calidad de las muestras de polisacárido purificado de Streptococcus pneumoniae, dando resultados comparables con el método recomendado en la Farmacopea Europea, 2011(AU)


Introduction: complexity and diversity in the structure of Streptococcus pneumoniae capsular makes the analytical methodology for characterization and quality control a troublesome aspect. The colorimetric m/hydroxibiphenil method devised by Blumenklrantz and Asboe-Hansen in 1973 allows reducing the disadvantages of the suggested method in the European Pharmacopea 6th edition, 2011. Objective: to validate the m-hydroxybiphenil method for quantitation of uronic acid in purified Streptococcus pneumonia polysaccharides. Methods: the length of validity of a sodium tetraborate solution, responsible for generating the analytical response, was estimated, and additionally, a methodology for quantitation of uronic acid by the m-hydroxybiphenil method was selected in which a standard galacturonic acid solution at 1mg/ml was used. The validation parameters were evaluated as follows: linearity, accuracy, precision, range and specificity, according to the present requirements. This method was compared with the carbazol method described in the European Pharmacopea 6th edition, 2011 for quantitation of uronic acid. Results: it was demonstrated that the useful lifetime of the sodium tetraborate solution was 24 hours. The m-hydroxybiphenil method was specific, linear, accurate and precise in the range of 2 to 20 ?g/mL because the set acceptance criteria were satisfactorily complied with for each of them. The comparison of the suggested method with the standardized method yielded that no statistically significant differences exist between them. Conclusions: the colorimetric m-hydroxybiphenil method proved to be valid for the quality control of purified Streptococcus pneumonia polysaccharide samples and the results are comparable to those of the recommended method in the European Pharmacopea, 2011(AU)


Subject(s)
Humans , Pneumococcal Infections/epidemiology , Carbazoles , Colorimetry/methods , Validation Studies as Topic
8.
Med. lab ; 21(9/10): 493-496, 2015.
Article in Spanish | LILACS | ID: biblio-907793

ABSTRACT

Antitrombina III Antithrombin IIICódigo SCPC (Sociedad Colombiana de Patología Clínica): 10700. Código CUPS (CodificaciónÚnica de Procedimientos en salud): 902007. Sección: Hematología. Nivel de complejidad:alto. Metodología: colorimetría. Sinónimos: actividad de antitrombina.DefiniciónLa prueba de antitrombina III, un inhibidor natural de la coagulación, es útil para el diagnóstico del riesgo de trombosis o bien para definir la etiología en pacientes con episodios previos de tromboembolismo venoso. La actividad de la antitrombina se determina mediante un método colorimétrico a partir de muestras de plasma citratado.Espectro clínico de aplicaciónLa antitrombina es una glicoproteína dependiente de vitamina K, sintetizada en el hígado, que actúa como un inhibidor natural de la coagulación mediante la unión irreversible a la trombina y al factor Xa y, en menor medida, a los factores Ixa, XIa, XIIa, plasmina y calicreína. De esta forma, la antitrombina inhibe múltiples puntos la cascada de la coagulación y, debido a esto, su deficiencia funcional o cuantitativa predispone a la trombosis.En la población general la deficiencia de antitrombina es variable, afectando alrededor de una por cada 500-5.000 personas. La deficiencia de antitrombina puede corresponder a una deficienciaen la concentración, la actividad o ambas; a su vez, puede ser hereditaria, congénita o adquirida. Existen varios tipos de deficiencia congénita y hereditaria que se resumen en la tabla 1. Por su parte, la deficiencia adquirida de antitrombina se puede presentar en pacientes con enfermedades hepáticas, coagulación intravascular diseminada, síndrome nefrótico, bypass cardiopulmonar, sepsis o con historia de nacimiento prematuro.


Subject(s)
Humans , Antithrombin III , Colorimetry , Hematology , Thrombosis
9.
Arq. bras. med. vet. zootec ; 65(5): 1472-1482, out. 2013. graf
Article in English | LILACS | ID: lil-689767

ABSTRACT

The objective of this work was to evaluate combinations between acid digestion techniques and spectrophotometric quantification to measure chromium concentration in cattle feces. Digestion techniques were evaluated based on the use of nitric and perchloric acids, sulfuric and perchloric acids, and phosphoric acid. The chromium quantification in the solutions was performed by colorimetry and by atomic absorption spectrophotometry (AAS). When AAS was used, the addition of calcium chloride to the solutions as a releasing agent was also evaluated. Several standard samples containing known chromium contents were produced (0, 2, 4, 6, 8 and 10g of chromium per kg of feces) using cattle feces obtained from three different animals to evaluate the accuracy of the different combinations of techniques. The accuracy was evaluated by adjusting a simple linear regression model of the estimated values on the actual values of chromium content in the standard samples. Regardless of the digestion technique, the chromium content estimates in the standard samples obtained by colorimetry were not accurate (P<0.05). Considering the AAS quantification, the digestion techniques based on nitric and perchloric acids and based on sulfuric and perchloric acids provided complete chromium recovery (P>0.05). The use of the digestion technique in phosphoric acid provided incomplete recovery of the fecal chromium (P<0.05). Subsequently, the digestion techniques in nitric and perchloric acids and digestion in sulfuric and perchloric acids, both evaluated by AAS, were compared using 84 cattle feces samples. The results indicate that these techniques provide similar (P>0.05) fecal chromium contents.


Objetivou-se avaliar combinações entre técnicas de digestão ácida e quantificação espectrofotométrica para estimar a concentração de cromo em amostras de fezes bovinas. Foram avaliadas técnicas de digestão baseadas na utilização de ácidos nítrico e perclórico, ácidos sulfúrico e perclórico e ácido fosfórico. A quantificação da concentração de cromo nas soluções foi realizada por colorimetria e por espectrofotometria de absorção atômica (EAA). Na quantificação por EAA, foi avaliada a adição de cloreto de cálcio como agente de liberação. Amostras-padrão contendo quantidades conhecidas de cromo foram produzidas (0, 2, 4, 6, 8 e 10g de cromo por kg de fezes) utilizando-se fezes bovinas obtidas de três animais diferentes, para avaliar a acurácia das diferentes técnicas. A acurácia foi avaliada pelo ajustamento de modelo de regressão linear simples dos valores estimados sobre os valores reais de cromo nas amostras-padrão. Independentemente da técnica de digestão ácida, as estimativas da concentração de cromo nas amostras-padrão obtidas por colorimetria não foram acuradas (P<0,05). Considerando-se a quantificação de cromo por EAA, as técnicas de digestão baseadas nos ácidos nítrico e perclórico e nos ácidos sulfúrico e perclórico promoveram completa recuperação de cromo (P>0,05). A utilização da técnica de digestão em ácido fosfórico promoveu recuperação incompleta do cromo fecal (P<0,05). Posteriormente, as técnicas de digestão em ácidos nítrico e perclórico e em ácidos sulfúrico e perclórico, ambas avaliadas por EAA, foram comparadas utilizando-se 84 amostras de fezes bovinas. Os resultados indicam que aquelas combinações de técnicas promovem resultados similares (P>0,05) da concentração fecal de cromo.


Subject(s)
Animals , Cattle , Cattle , Digestion , Feces/chemistry , Colorimetry , Colorimetry/veterinary , Spectrophotometry
10.
Ciênc. rural ; 43(7): 1251-1257, jul. 2013. tab
Article in Portuguese | LILACS | ID: lil-679244

ABSTRACT

O objetivo deste estudo foi avaliar fontes de concentrados proteicos vegetais alternativos em substituição ao farelo de soja sobre o desempenho e composição centesimal de jundiás (Rhamdia quelen) e coloração dos filés. Foram utilizadas 20 unidades experimentais, com capacidade de 90L cada uma, onde 400 peixes permaneceram alojados durante 45 dias. Os juvenis de jundiá possuíam 11,5±5,0cm e peso inicial de 10,4±5,5g. Foram avaliadas quatro fontes de concentrados proteicos, sendo eles: dieta controle, tendo o farelo de soja com base proteica; CL: dieta contendo concentrado proteico de crambe + concentrado proteico de linhaça; CLGM: composta por concentrado proteico de crambe + concentrado proteico de linhaça + concentrado proteico de folha de mandioca + concentrado proteico de farelo de girassol e GM: constituída por concentrado proteico de farelo de girassol + concentrado proteico de folha de mandioca. Aos 30 e 45 dias, foram avaliados os parâmetros de crescimento (peso, fator de condição, taxa de crescimento específico, ganho em peso diário e relativo, taxa de eficiência proteica e conversão alimentar aparente) e avaliação centesimal do peixe inteiro e filé (umidade, proteína bruta, gordura e cinzas). Além disso, aos 45 dias, foi realizada a avaliação instrumental da cor nos filés. Ao final do período experimental, foram observadas diferenças significativas para os parâmetros de crescimento e avaliação centesimal, sendo que os animais alimentados com as dietas CL apresentaram maior crescimento (13,8cm), taxa de crescimento específico (2,43% dia-1), ganho em peso diário (0,41g dia-1), ganho em peso relativo (108,3%) e menor conversão alimentar (1,21), comparado às dietas contendo concentrado proteico de girassol e concentrado proteico de folhas de mandioca. Observou-se também que os animais alimentados com as dietas GM e CLGM apresentaram uma pigmentação amarelada nos filés. Conclui-se que os animais alimentados com a dieta CL obtiveram os maiores índices de desempenhos, podendo ser utilizada como alimento na formulação de dietas para esta espécie. As demais combinações não redundaram em resultados melhores que a dieta controle e CL.


The aim of this study was to evaluate vegetable protein concentrates to replace soybean meal (traditional protein) on performance and chemical composition of catfish (Rhamdia quelen) and its influence on the coloration of the fillets. We used 20 experimental units (EU), with a capacity of 90L each, where 400 fish were rearing for 45 days. Juvenile catfish had 11.5±5.0cm and an initial weight of 10.4±5.5g. We evaluated four diets with different sources of protein concentrates, which are: Control, conventional diet using soybean meal as source of protein; CL: diet containing protein concentrate crambe meal protein concentrate; CLGM: protein concentrate consisting of crambe meal protein concentrate protein concentrate cassava leaf protein concentrate and GM sunflower meal: protein concentrate consisting of sunflower meal protein concentrate cassava leaf. At 30 and 45 days were evaluated growth parameters (weight, condition factor, specific growth rate, daily weight gain and relative protein efficiency ratio and feed conversion) and proximate evaluation of the whole fish and fillet (humidity, crude protein, fat and ash). In addition, the 45-day evaluation was made color instrumental in fillets. At the end of the experiment, significant differences were observed for growth parameters and proximate, and the animals fed the LC diets had higher growth (13,8cm), specific growth rate (2,43% day-1), daily weight gain (0,41g day-1), relative weight gain (108,3%) and lower feed conversion (1,21) compared to diets containing protein concentrate of sunflower and cassava leaves. We also observed that animals fed on GM diets and CLGM showed a yellowish pigment in the fillets. It is concluded that animals fed the CL diet had the highest levels of performance and can be used as food in the formulation of diets for this species. All others combinations do not showed no better results than the control diet and CL.

11.
Rev. Inst. Adolfo Lutz ; 70(3): 296-301, set. 2011. tab
Article in Portuguese | LILACS, SES-SP, SESSP-CTDPROD, SES-SP, SESSP-ACVSES, SESSP-IALPROD, SES-SP, SESSP-IALACERVO | ID: lil-644376

ABSTRACT

A coloração dos produtos cárneos, conferida pela mioglobina, é um fator importante para aceitabilidade do consumidor e indicativo de qualidade. Há associação entre a oxidação lipídica com esse pigmento e sua influência na coloração da carne, o que induz a realizar estudos sobre antioxidantes. Este trabalho investigou a ação da ficocianina, α-tocoferol e ácido ascórbico, em substituição parcial ao nitrito, na manutenção da cor da linguiça mista defumada. No preparo das linguiças foram utilizados seis tratamentos (0,005% nitrito de sódio + antioxidante) e um controle (0 A) contendo somente nitrito. Os tratamentos testados foram: 1 A e 1 B (ácido ascórbico), 2 A e 2 B (α-tocoferol), 3 A e 3 B (ficocianina). As linguiças foram defumadas durante oito horas a 65 ºC e armazenadas a 4 ºC e foram analisadas quanto a cor, pH e nitrito residual.O tratamento 2 B mostrou-se mais eficiente na manutenção da cor vermelha, pela ação doα-tocoferol. A incorporação do ácido ascórbico (tratamento 1 A) acelerou a redução da metamioglobinae a conversão do nitrito em óxido nítrico. A adição de ficocianina (tratamento 3 A) reduziu a intensidadede cor vermelha e aumentou a intensidade de coloração amarela e a luminosidade.


Subject(s)
Antioxidants , Colorimetry , Myoglobin , Nitrites , Meat Products
12.
Rev. Inst. Adolfo Lutz ; 70(3): l3016-301, set. 2011. tab
Article in Portuguese | LILACS, VETINDEX | ID: biblio-1489475

ABSTRACT

A coloração dos produtos cárneos, conferida pela mioglobina, é um fator importante para aceitabilidade do consumidor e indicativo de qualidade. Há associação entre a oxidação lipídica com esse pigmento e sua influência na coloração da carne, o que induz a realizar estudos sobre antioxidantes. Este trabalho investigou a ação da ficocianina, α-tocoferol e ácido ascórbico, em substituição parcial ao nitrito, na manutenção da cor da linguiça mista defumada. No preparo das linguiças foram utilizados seis tratamentos (0,005% nitrito de sódio + antioxidante) e um controle (0 A) contendo somente nitrito. Os tratamentos testados foram: 1 A e 1 B (ácido ascórbico), 2 A e 2 B (α-tocoferol), 3 A e 3 B (ficocianina). As linguiças foram defumadas durante oito horas a 65 ºC e armazenadas a 4 ºC e foram analisadas quanto a cor, pH e nitrito residual.O tratamento 2 B mostrou-se mais eficiente na manutenção da cor vermelha, pela ação doα-tocoferol. A incorporação do ácido ascórbico (tratamento 1 A) acelerou a redução da metamioglobinae a conversão do nitrito em óxido nítrico. A adição de ficocianina (tratamento 3 A) reduziu a intensidadede cor vermelha e aumentou a intensidade de coloração amarela e a luminosidade.


Subject(s)
Antioxidants , Colorimetry , Myoglobin , Nitrites , Meat Products
13.
Surg. cosmet. dermatol. (Impr.) ; 3(1): 37-40, mar. 2011. tab, ilus
Article in English, Portuguese | LILACS-Express | LILACS | ID: lil-602557

ABSTRACT

Introdução: Diversos tratamentos têm sido propostos para o melasma porém todos com variáveis limitações. Em 2006 a FDA aprovou a fototermólise fracionada para o tratamento dessa dermatose. Objetivos: Avaliar a evolução clínica, através de métodos objetivos, de pacientes com melasma tratadas isoladamente com a fototermólise fracionada.Métodos: Estudo de intervenção terapêutica, aberto, prospectivo, de 20 pacientes com diagnóstico clínico de melasma. Os critérios de exclusão foram terapia hormonal, uso de retinoides orais, infecções cutâneas, gravidez e amamentação. Foram realizadas três sessões de laser fracionado não ablativo a intervalos de quatro semanas. Os parâmetros utilizados foram: Pulso = 15ms e energia crescente a cada sessão = 8 - 10 - 12J. Masi e colorimetria (com índices ITA, L, a, b) foram os parâmetros de avaliação utilizados antes do tratamento e quatro semanas após sua última sessão. Resultados: Completaram o estudo 18 pacientes do sexo feminino com idade entre 23 e 48 anos e fototipos de II a IV (Fitzpatrick). Realizaram-se o Masi em 17 e a colorimetria nas 18 pacientes. Houve redução estatisticamente significante da escala Masi (p < 0,0001, IC95%) e aumento médio dos índices L (p = 0,0003, IC 95%) e ITA (p = 0,0017, IC 95%) na colorimetria, traduzindo redução da pigmentação. Conclusões: A fototermólise fracionada mostrou-se opção segura e eficaz para o tratamento do melasma, apontando para alternativa a se somar aos tratamentos convencionais.

14.
Rev. dental press estét ; 7(2): 82-100, abr.-jun. 2010. ilus
Article in Portuguese | LILACS, BBO | ID: lil-557487

ABSTRACT

Uma adequada seleção de cor em Odontologia é imprescindível para se alcançar um bom resultado estético. O método mais difundido para realizar tal seleção é o visual, no qual se realizam comparações simultâneas entre a cor do dente e a cor de uma escala. Dessa forma, o método de seleção visual da cor gera muitas dúvidas, que variam desde a técnica de seleção até a escala mais adequada para a equiparação da cor. O conhecimento dos aspectos inerentes à estrutura dentária, à fonte de luz, às escalas e até mesmo à pessoa que está observando a cor deve ser considerado durante a seleção. Além disso, todas essas informações devem ser corretamente transmitidas ao técnico de laboratório para que o resultado final seja o desejado. O presente artigo reúne as principais informações referentes aos dentes, fonte luminosa, observador e escalas disponíveis, assim como apresenta uma sugestão de mapa cromático para comunicação laboratorial.


Subject(s)
Colorimetry , Dental Prosthesis , Vision Screening/methods , Color , Dentin , Dentistry , Esthetics, Dental
15.
Rev. Inst. Adolfo Lutz ; 60(1): e35145, 2001. tab, graf
Article in Portuguese | LILACS, ColecionaSUS, SES-SP, CONASS, SESSP-ACVSES, SESSP-IALPROD, SES-SP, SESSP-IALACERVO | ID: lil-303601

ABSTRACT

Foram comparados os métodos de cromatografia líquida de alta eficiência (CLAE) e colorimétrico para determinaçäo de colesterol em carnes. As etapas anteriores à quantificaçäo säo semelhantes nos dois métodos, consistindo da extraçäo dos lipídios, saponificaçäo e extraçäo da matéria insaponificável. O método por CLAE utiliza uma coluna de C18, fase móvel de acetonitrila:isopropanol (7:30) e detecçäo fixada em 210nm. O método colorimétrico envolve a reaçäo com ácido sulfúrico concentrado e ácido acético saturado com sulfato ferroso, e leitura a 490nm 10min após resfriamento. Foi analisado um total de 28 amostras de carnes bovina e suína. Näo houve diferença significativa nos resultados obtidos pelos dois métodos para todas as amostras analisadas. Portanto, qualquer um dos métodos avaliados pode ser utilizado com segurança. O método colorimétrico é mais barato e rápido, mas precisa de controle rigoroso das condiçöes da reaçäo e utiliza reagentes corrosivos. O método por CLAE näo exige atençäo constante, mas é mais oneroso e requer experiência no uso do aparelho. (AU)


A colorimetric method and an HPLC method were compared for the determination of cholesterol in meat. The steps preceding measurement were similar, consisting of extraction of the lipids,saponification and extraction of unsaponificable matter. The HPLC method utilized a C18 column with acetonitrile:isopropanol (70:30) as mobile phase; detection was set at 210 nm. The colorimetric method involved reaction with concentrated sulfuric acid and acetic acid saturated with ferrous sulfate, the absorbance being measured at 490 nm 10 minutes after cooling. No significant difference was seen in the results of the two methods for the 28 samples of different cuts of pork and beef analyzed; thus, either method can be reliably used. The colorimetric method is rapid and low-cost, but requires rigorous control of reaction conditions and uses corrosive reagents. The HPLC method does not need constant attention, but is expensive and requires experience in the operation of the instrument. (AU)


Subject(s)
Cholesterol , Chromatography, High Pressure Liquid , Colorimetry , Food Analysis , Meat
SELECTION OF CITATIONS
SEARCH DETAIL